1. Overview
- Display: Custom lcd
- Printer Output: EPS-P30 (option) can be connected
- Clock Function: Yes (always displayed during measurement)
- Data Memory: 1000 data
- Power Consumption (W): Approx. 0.009 (when using 3V battery)
- Calibration: Cell constant, (temperature) 1 point
- Connection sensor: (ch1) Electric conductivity
- Output Specifications: (Conductivity / Resistivity / Salt) 0-1V FS (range), (Range) 100mV / range, (Temperature) 0-1V (0-100 ° C)
- Analog Output: (ch1) Number of outputs / 3, item / measured value, temperature, range (electric conductivity / resistivity only)
- Outer dimensions, Width W x Height H x Depth D (mm): 68×35×173
- Memory function: Interval / Present (arbitrary setting from 1 second to 99 minutes 59 seconds or 2 minutes to 99 hours 59 minutes)
- Waterproof specification: IP67 (valid when the sensor is connected and when the external I / O block is masked)
- Battery Life (hours): About 600
- Display Range
(Conductivity) 0 ~ 200.0μS / m, 0 ~ 2.000mS / m, 0 ~ 20.00mS / m, 0 ~ 200.0mS / m, 0 ~ 2.000S / m, 0 ~ 20.00S / m, 0 ~ 200.0 S / m (electrical resistivity) 0.05-2.000Ω ・ m, 0-20.00Ω ・ m, 0-200.0Ω ・ m, 0-2.000kΩ ・ m, 0-20.00kΩ ・ m, 0-200.0kΩ ・ m, 0 ~ 2.000MΩ ・ m, 0 ~ 20.00MΩ ・ m (Salt content (NaCl conversion value from electrical conductivity)) 0 ~ 4.04%, (Temperature) -5 ~ 110.0 ℃
- Mass (g): Approx. 280 (including batteries)
- Type of Switching: (Range) Electrical conductivity / automatic, resistivity / manual (unit) Electrical conductivity / resistivity, switchable between SI unit (S / m, Ω ・ m) and old unit (S / cm, Ω ・ cm)
- Repeatability: Instrument body / (Electric conductivity) ± 0.5% FS, (Electric resistivity) ± 0.5% FS, (Salt content) ± 0.5% FS, (Temperature) ± 0.2 ° C
- Interface: (RS-232C non-isolated) Device / PC or external printer EPS-P30 (option), communication specification / (communication method) asynchronous mode, (baud rate) 19200bps, (character length) 8 bits, (parity) not available, (Stop bit) 1 bit
- Type: General use
- Operating Temperature / Humidity Range: 0 to 45 ° C (optional AC adapter, 0 to 40 ° C when using an external printer)
- Temperature Compensation: Switch between auto / manual / none. (Temperature compensation method) Linear / pure water double temperature compensation. Reference temperature 25 ° C. Temperature coefficient 0 ~ 9.99%. (Optional setting)
- Automatic Hold: Yes (stable judgment value: fixed)
- Included Accessories: Hand strap OTZ00006, AA alkaline batteries (for testing) (2), instruction manual
- Measurement Method: AC 2-electrode method
- Power Supply: Single 3 form alkali dry cell / two nickel-metal hydride batteries or exclusive AC adapter (6VA option)
Reviews