1. Overview
- Quick & Easy Sample Clean-Up
- For Dioxin, PCB & PBDE Analysis
- After 30 years of leading automation in the field of Dioxin & PCBs analysis, FMS introduces EZprep 123 to further simplify the dioxin sample preparation process and make it easier to perform. The EZprep 123’s impressive performance allows Dioxin labs to reduce turnaround time and increase the quality of the analysis while reducing the cost.
Simple to operate – No Computer or Electronics - Fast – 30 to 45 Minutes
- Green Technology – Zero DCM
- High Throughput – 6 Samples in Parallel
- Quality Consumables – Guaranteed Certified Columns
- Low Solvent – As Low as 90 ml Per Sample
- Reliable – No Electronic or Mechanical Components to Fail. No Cross-Contamination
- Economical – Column Kits to Meet Your Sample Matrix
- Affordable – No Capital Equipment Costs
2. Outstanding Advantages
- Green Technology – Zero DCM
The EZprep 123 uses Zero DCM in the cleanup process. By design it produces greater efficiency to perform clean up while greatly reducing solvent consumption.
- Fast – 30 to 45 Minutes
Depending on the Sample Matrix and Lipid content, samples can be run in 30 to 45 minutes. Column kits designed to meet different sample lipid content allow for fast sample processing. The system is able to turn around up to 64 samples in a day.
- Low Solvent – As Low as 90 ml Per Sample
Column kits designed for samples with different lipid contact allow for using the lowest possible amount of solvent to process a sample. High Throughput 100’s of samples Per Day EZprep 123 performs sample cleanup for 6 samples simultaneously achieving high recoveries and excellent precision for all analytes. The compact design of EZprep 123 allows several apparatuses to be placed in one hood performing hundreds of samples per day. - Simple and Quick – 3 Easy Steps
EZprep 123 uses a rotary work station to perform the entire sample cleanup quickly. One needs only to fill solvent reservoirs, install columns and start the process. From sample loading, to elution and fraction collection takes just 3 simple steps. Dioxins, PCBs and PBDEs are collected in tubes with GC vials ready for GCMS Analysis.
3. Specifications
- L-13.5″
- W- 19.75″
- H-30.5″
4. Applications
Applications
- Food
- Butter
- Air
- Meat
- Oil
- Soil
- Fish
- Milk
- Fly ash
- Feed
- Blood
- Emission
- Water
- Tissues
- Sludge
Application notes:
- EPA 1613 Semi Automated Clean Up for POPs in Fish Oil by EZPrep 123
- EPA 1613 Semi Automated Clean Up for POPs in Fish by EZPrep 123
- EPA 1613 and 1668C Semi-Automated Cleanup for POPs Analysis in Oil Samples by EZPrep 123
- Low Solvent DCM-Free Semi-Automated Negative Pressure Sample Clean Up for POPs Analysis by EZPrep 123
- EPA 1613 and 1668C Semi-Automated Cleanup of POPs in Sample Extracts in Soil by EZPrep 123
- EPA 1613 and 1668C Semi-Automated Cleanup of Sample Extracts for POPs Analysis in Soil by EZPrep 123
- Extractable Petroleum Hydrocarbon Fractionation and Cleanup by EZPrep 123
- Semi Automated Clean Up for Persistent Organic Pollutants Analysis in Oil Samples – Complete Separation of PCDD/Fs and PCBs Using Florisil in Clean Up
- Low Solvent, DCM-Free, Semi Automated, Negative Pressure Sample Clean Up for Persistent Organic Pollutants Analysis using Pre Packaged Certified Columns
- Semi Automated Clean Up for Persistent Organic Pollutants in Fish Oil – PCDDFs Analysis for Sample Extracts in Toluene
- Semi Automated Clean Up for Persistent Organic Pollutants in Fish – PCDDFs and PCBs Analysis for Sample Extracts in Toluene
- Semi Automated Clean Up for Persistent Organic Pollutants in Fish – PCDDFs Analysis for Sample Extracts in Toluene
- Semi Automated Clean Up for Persistent Organic Pollutants Analysis in Environmental Samples – Complete Separation of PCDDFs and PCBs for Sample Extracts in Toluene
- Fast Semi-Automated Extractable Petroleum Hydrocarbons Fractionation and Cleanup