Introduction
This disintegration tester measures the breakdown time of tablets EDI-2. It is a two-station unit. The device uses a bathless heating system. This saves time, water, and electricity. It provides accurate temperature control for reliable testing. The tester is a compact solution for pharmaceutical quality control labs.
Product Overview
The EDI-2 is a two-station disintegration tester. It operates with a single motor and timer. The bathless heating system warms media 50% faster than traditional water bath models. This design enhances visual observation and is maintenance-free. Features include snap-click™ basket loading and green bottom illumination. At the end of a test, the baskets automatically park in the top position. An alarm also sounds to notify the user. The unit supports standard and veterinary tablet testing.
Key Features
- Features a bathless heating system to save time, water, and electricity.
- Heats media 50% faster than testers with a water bath.
- Has two test stations operated by a single motor and timer.
- Includes two individual sensors to measure beaker temperature directly.
- Provides green bottom illumination for clear visibility of the process.
- Automatically parks baskets at the top with an alarm when the test ends.
- Uses Snap-click™ loading for easy, swivel-free basket handling.
- Has a maintenance-free smooth drive.
- Supports optional bolus baskets for veterinary tablets.
Technical Specifications
Specification | Value |
Model | EDI-2 |
Number of Stations | 2 |
Number of Motors | 1 |
Number of Strokes | 30 ± 0.5 strokes/min |
Stroke Height | 55 mm ± 2 mm |
Temperature Range | 20°C to 39.9°C |
Temperature Resolution | ± 0.1°C |
Timer | Dual range (sec/min/hr) |
Display | 4 digit LED |
Dimensions (L x W x H) | 400 x 365 x 510 mm |
Weight | 18 kg |
Applications
- Quality control testing of standard tablets and capsules.
- Disintegration testing for veterinary tablets (using optional bolus baskets).
- Pharmaceutical R&D and formulation studies.
- Routine testing in a laboratory setting.
Pricing
Please contact us for consultation and detailed quotation.
FAQ
1. What is the main benefit of bathless heating?
The bathless system saves time, water, and electricity. It also heats media 50% faster than water bath models and requires no maintenance for the heating system.
2. Are the two stations independent?
No, the two baskets are controlled by a single motor and a single timer. They start and stop at the same time.
3. What happens at the end of a test?
When the timer finishes, the baskets automatically move to the highest position (parking). An audible alarm also sounds to alert the user.
4. Is this tester suitable for large tablets?
Yes, the EDI-2 supports an optional three-tube bolus basket assembly. This makes it suitable for testing large veterinary tablets.
5. How is the temperature measured?
The system uses two individual temperature sensors (probes). These probes are placed directly into the beakers to measure the actual media temperature accurately.
Conclusion
The EDI-2 disintegration tester offers an efficient solution for labs. Its bathless heating and user-friendly features simplify testing. The unit is reliable and easy to maintain. Contact us to learn more about how the EDI-2 can benefit your laboratory.