Automatic titrator AUT-801
Introduction
The Automatic titrator AUT-801 is an advanced laboratory analytical instrument manufactured by DKK-TOA CORPORATION. Designed to optimize and automate complex titration processes, the AUT-801 delivers high precision, saves time, and minimizes human error. This device is an indispensable tool in quality control, research, and development laboratories, particularly in the food and chemical industries.
Product Overview
The AUT-801 stands out with its combination of high performance and flexibility. The machine is equipped with various powerful titration support functions, notably the Semi-auto function, which shortens titration time while maintaining performance comparable to manual titration. Additionally, users can manually set the end-point detection (Set detection point function) to suit specific analytical methods. One of the most superior features of the AUT-801 is its Dual system capability, allowing for simultaneous execution and display of two titrations, doubling work productivity. The device also integrates a validation support function to ensure the reliability of results and has extensive connectivity with turntables (TTT-710) or other automatic sampling devices to form a fully automated analytical system.
Key Features
- Diverse Support Functions: Powered by various functions to optimize all types of titration reactions.
- Semi-auto Function: Significantly speeds up titration while ensuring accuracy akin to traditional manual titration methods.
- Customizable End-point Detection: Allows users to manually set the detection point, increasing flexibility for difficult samples.
- Dual System: Capability to perform and display two independent titration processes simultaneously, maximizing laboratory throughput.
- Validation Support: Integrates tools to support method and instrument validation, meeting stringent quality management standards.
- Automation Scalability: Easily connects to sample turntables (like TTT-710) and automatic sampling devices for unattended batch processing.
Technical Specifications
| Parameter | Details |
|---|---|
| Model | AUT-801 |
| Measurement Item | Automatic Titrator |
| Titration Modes | Automatic, Semi-auto, Manual end-point setting |
| System Configuration | Supports Single system and Dual system |
| GLP/GMP Features | Validation support function |
| Connectivity | Compatible with TTT-710 turntable and other automatic sampling devices |
Applications
- Food and Beverage Industry: Determining total acidity, salt content, vitamin C, peroxide value in fats and oils, and other quality indicators.
- Chemical Industry: Analyzing chemical purity, acid-base titrations, redox titrations, complexometric titrations.
- Pharmaceuticals: Testing active ingredient content, quantifying components in drugs according to pharmacopeial standards.
- Water and Environmental Treatment: Measuring water hardness, alkalinity, chemical oxygen demand (COD), and other environmental parameters.
Pricing
Please contact us for consultation and detailed quotation.
Frequently Asked Questions (FAQ)
1. How does the Semi-auto function on the AUT-801 work?
The Semi-auto function allows the titrator to add reagent quickly during the initial stages of the reaction and automatically slow down as it approaches the end-point. This significantly shortens the total titration time while ensuring high accuracy at the equivalence point, similar to the skills of an experienced analyst.
2. What are the benefits of the Dual system?
The Dual system allows you to connect two burettes and two electrodes to the same AUT-801 main unit. You can run two completely different (or identical) titrations on two different samples simultaneously, and monitor both processes on the same screen, effectively doubling your analytical throughput.
3. Can the machine fully automate the analysis process?
Yes, the AUT-801 is designed to easily integrate with peripheral devices like sample turntables (TTT-710). When combined, the system can automatically take samples, add solvents, titrate, wash electrodes, and move to the next sample without human intervention.
4. What does the validation support function include?
This function provides automated routines to check the accuracy of the burette (dispensed volume check) and the stability of the electrode signal, making it easy for users to perform IQ/OQ/PQ requirements according to GLP/GMP standards.
5. Can I set the titration end-point as desired?
Yes, with the “Set detection point” function, you can specify a particular potential (mV) or pH value as the end-point for titration reactions that do not have a clear inflection point or as required by specific analytical methods.
Conclusion
The Automatic titrator AUT-801 from DKK-TOA is a comprehensive analytical solution, combining speed, precision, and excellent scalability. With advanced features like the simultaneous Dual system, smart Semi-auto mode, and automated connectivity, the AUT-801 perfectly meets the high-volume and stringent analytical demands in the food, chemical, and pharmaceutical industries. Contact us today to receive in-depth consultation and the best quote for this titration system.











Reviews